Enphase Environ Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Thermostats Enphase Environ. enphase Environ User manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Smart Thermostat

Installation and Operation Manual EnvironTM Smart Thermostat

Page 2

10 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 What wires do you have? Make sure your wires are labeled. This may require you to find the ot

Page 3 - FCC Compliance

11 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 1. Fan wires out as illustrated with the Environ below the wall opening. As in the example,

Page 4 - Table of Contents

12 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Mount the Environ to Wall 1. Hold the Environ against the wall with the wires coming over th

Page 5 - Safety Instructions

13 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 3. Press the purple MENU button on the control bar and then press HVAC SET-UP. 4. Press to hi

Page 6

14 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 4. Select the number of stages of compression for your heat pump system (1 or 2) by pressing

Page 7

15 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 To check COOL mode (do not operate the AC if outside temperature is below 65oF): 1. Press the

Page 8 - Location

16 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 4 Configuring the Environ Calibration Your thermostat was calibrated at the factory. We rec

Page 9 - Remove the Old Unit

17 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Humidifier To use the Environ internal humidistat to control an external humidifier unit, c

Page 10

18 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 5 Environ Interface to Envoy The Environ programmable communicating thermostat interfaces to

Page 11 - Connect Wires

19 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Only unmated Environs will link to the Envoy. Once an Environ links to the Envoy, the two wil

Page 12

2 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01

Page 13

20 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 6 Operating the Environ through Enlighten You can control the Environ thermostat directly,

Page 14 - Check HVAC System

The Environ summary contains the following elements: Current Temperature: This shows the ambient temperature where the Environ is installed. Setti

Page 15

22 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Configuration and Programs

Page 16

23 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 The Environ Configuration and Programs screen lets you control your temperature and mode usi

Page 17

24 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Time Comfort Range 6:00 AM 70o – 78o F 10:00 PM 62o – 82o F Edi

Page 18

25 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Smartphone Access The Summary and Configuration function above may be accessed via the smart

Page 19

26 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 7 Environ Local Interface To program or adjust your Environ on the device itself, simply pre

Page 20

27 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Home Screen The Home screen displays when the unit is operating. Pressing the green HOME i

Page 21

28 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 buttons to select your hold temperature. The Hold icon will display on the HOME screen indica

Page 22

29 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Menu Functions Program Settings The Environ is designed for fast and easy programming wit

Page 23 - Weekdays:

3 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Contact Information Enphase Energy Inc. 201 1St Street Petaluma, CA 94952 Phone: 707-763-4784

Page 24

30 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Calendar Programming Method You can use the Calendar screen to review your current Environ

Page 25

31 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Comfort Settings The Comfort Settings on the Environ allow you to maintain consistent comf

Page 26

32 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Chirp set Press this icon to turn the audible chirp sound on or off. F/C Set Press this

Page 27

33 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 dehumidify and the thermostat is also calling for COOL <HTS+TST> (HST=humidistat, TST=t

Page 28

34 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 HVAC Set-up This function allows you to configure the Environ to control your HVAC system. Th

Page 29

35 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 5. Press HOME to return to the Home screen. Set-Up for Heat Pump systems (up to 3 Stages):

Page 30

36 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 this range press RANGE +/- and use the +/- buttons to adjust up and down. FULL: No changes c

Page 31

37 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Save Energy Button The Save Energy feature on the Environ provides a simple, easy-to-use way

Page 32 - to ALWAYS or HST+TST

38 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 COOL: This will operate the cooling portion of your HVAC system until it is turned off. HEAT:

Page 33

39 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Wire Reference Chart Your Wires Environ Terminal R or V or VR RH and RC Single power for HE

Page 34

4 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Table of Contents 1 Important Safety Information ...

Page 35

40 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Trane Products B C W or W1 or X2 W2 Zoned Systems Wire Reference Chart Your Wires Env

Page 36

41 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 8 Appendix Limited Warranty Enphase Energy Inc. ("Enphase") has developed the Envi

Page 37 - programmed temperature

42 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 x If in-field troubleshooting does not solve the problem, Customer may request the RMA numbe

Page 38

43 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 MANUALS OR OTHER DOCUMENTATION. IN NO EVENT WILL ENPHASE BE LIABLE FOR ANY SPECIAL, DIRECT, I

Page 39 - Wire Reference Chart

44 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Enphase Energy Inc. 201 1St Street Petaluma, CA 94952 Phone: 707-763-4784 TOLL FREE: 877-79

Page 40

5 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 1 Important Safety Information Read this First This manual contains important instructions t

Page 41 - 8 Appendix

6 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 2 The Enphase Environ Smart Thermostat The Enphase Environ™ is the world’s first solar-integ

Page 42

7 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 devices and services such as the Environ Smart Thermostat. This capability enables Enphase Sys

Page 43

8 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 3 Environ Installation Your thermostat is a precise instrument; please handle it with care.

Page 44

9 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 x Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room